Remeha Boiler Error Code H.01.09
With H.01.09 the boiler measures gas pressure that is too low and blocks the start. Check that all gas taps are open. If the code keeps returning, an installer must check the inlet pressure and the gas pressure switch.
Also shown as: H01.09
Applies to: Remeha Ace platform (Tzerra Ace, Calenta Ace, Avanta Ace)
Common causes
- Gas inlet pressure too low, for example because a gas tap is not fully open
- Dirty gas filter, or a gas pressure switch that is fitted or adjusted incorrectly
What to check, in order
- Check that the gas tap at the boiler and at the gas meter is fully open, and that other gas appliances work normally.
- Reset the boiler once and see whether the blocking clears.
- If the code returns, have an installer check the gas supply pressure and the gas pressure switch.
Clear the code and test
- Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
- Make sure the boiler has power and the gas tap at the boiler is open.
- If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
- Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.
When to call a professional
Most cases are solved by the checks above. Book a technician if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code H.01.09, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.
Parts that may be involved
Gas pressure switch
Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.
Questions people ask about H.01.09
What does H.01.09 mean on a Remeha boiler?
H.01.09 means: Gas pressure too low (gas pressure switch operated). With H.01.09 the boiler measures gas pressure that is too low and blocks the start. Check that all gas taps are open. If the code keeps returning, an installer must check the inlet pressure and the gas pressure switch.
Can I fix Remeha H.01.09 myself?
Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.
How do I clear Remeha H.01.09?
Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.