Remeha Boiler Error Code E.04.02
With E.04.02 the flow temperature sensor gives no signal. Usually the sensor is faulty or the connection is loose. Replacement is a job for an installer.
Also shown as: E04.02
Applies to: Remeha Ace platform (Tzerra Ace, Calenta Ace, Avanta Ace)
Common causes
- Interrupted wiring or loose connector of the flow sensor
- Faulty flow sensor
What to check, in order
- Note the full code; a locking fault does not clear by itself.
- Check the water pressure and whether the gas tap is open, and only reset once a simple cause has been removed.
- If the code returns straight away, call a qualified installer; opening the boiler is not permitted.
Clear the code and test
- Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
- Make sure the boiler has power and the gas tap at the boiler is open.
- If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
- Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.
When to call a professional
This code usually points to a faulty part, wiring or the control board on a Remeha boiler. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code E.04.02, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.
Repair or replace?
This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.
Parts that may be involved
Flow temperature sensor
Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.
Questions people ask about E.04.02
What does E.04.02 mean on a Remeha boiler?
E.04.02 means: Flow temperature sensor is disconnected or reads below its range (sensor open). With E.04.02 the flow temperature sensor gives no signal. Usually the sensor is faulty or the connection is loose. Replacement is a job for an installer.
Can I fix Remeha E.04.02 myself?
Only the preliminary checks. Code E.04.02 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.
How do I clear Remeha E.04.02?
Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.