CodeMeaningFix level
E.00.04
also: E00.04
Return temperature sensor is disconnected or reads below its range (sensor open)Call a professional
E.00.05
also: E00.05
Return temperature sensor is short-circuited or reads above its rangeCall a professional
E.00.06
also: E00.06
The return temperature sensor is expected but not detected (no connection)Call a professional
E.00.07
also: E00.07
The difference between the return temperature and the flow temperature is too largeDIY checks first
E.00.16
also: E00.16
Hot water tank sensor (domestic hot water) is disconnected or reads below its rangeCall a professional
E.00.17
also: E00.17
Hot water tank sensor (domestic hot water) is short-circuited or reads above its rangeCall a professional
E.01.04
also: E01.04
Flame failure five times: the flame has dropped out repeatedlyDIY checks first
E.01.11
also: E01.11
The fan speed is outside its normal operating rangeCall a professional
E.01.12
also: E01.12
The return temperature is higher than the flow temperature (flow and return swapped)Call a professional
E.02.13
also: E02.13
The blocking input of the control is active (locking)Call a professional
E.02.15
also: E02.15
Time-out of the external CSU (no answer from the settings memory)Call a professional
E.02.17
also: E02.17
Communication error with the safety core in the gas valve control (feedback time exceeded)Call a professional
E.02.32
also: E02.32
Automatic topping up of the system takes too long (feedback time exceeded)DIY checks first
E.02.35
also: E02.35
A critical safety device has been disconnected (communication fault)Call a professional
E.02.39
also: E02.39
Insufficient pressure rise after automatic topping upDIY checks first
E.02.47
also: E02.47
The connection to the function groups has failed (function group not found)Call a professional
E.04.01
also: E04.01
Flow temperature sensor is short-circuited or reads above its rangeCall a professional
E.04.02
also: E04.02
Flow temperature sensor is disconnected or reads below its range (sensor open)Call a professional
E.04.03
also: E04.03
The measured temperature is above the safety limitDIY checks first
E.04.04
also: E04.04
Flue gas temperature sensor is short-circuited or reads above its rangeCall a professional
E.04.05
also: E04.05
Flue gas temperature sensor is disconnected or reads below its range (sensor open)Call a professional
E.04.07
also: E04.07
Deviation between flow sensor 1 and flow sensor 2Call a professional
E.04.08
also: E04.08
The safety input is open (air pressure differential switch operated)DIY checks first
E.04.09
also: E04.09
Deviation between flue gas sensor 1 and flue gas sensor 2Call a professional
E.04.10
also: E04.10
Five failed burner starts detectedDIY checks first
E.04.11
also: E04.11
The gas valve check (VPS) has failed: the valve leak test does not passCall a professional
E.04.12
also: E04.12
False flame detected before the burner startsCall a professional
E.04.13
also: E04.13
The fan speed is outside its normal operating rangeCall a professional
E.04.15
also: E04.15
The flue pipe is blockedDIY checks first
E.04.17
also: E04.17
The drive of the gas valve is faulty (gas valve fault)Call a professional
E.04.23
also: E04.23
Internal locking of the gas valve controlCall a professional
H.01.00
also: H01.00
Communication error with the safety core of the controlCall a professional
H.01.05
also: H01.05
Maximum difference between flow and return temperature exceededDIY checks first
H.01.08
also: H01.08
The heat exchanger temperature rises too quickly (maximum temperature gradient exceeded)DIY checks first
H.01.09
also: H01.09
Gas pressure too low (gas pressure switch operated)DIY checks first
H.01.14
also: H01.14
The flow temperature has exceeded the maximum operating valueDIY checks first
H.01.21
also: H01.21
The flow temperature rises too quickly during hot water operation (maximum DHW temperature gradient exceeded)DIY checks first
H.02.02
also: H02.02
The boiler is waiting for the configuration number (configuration error)Call a professional
H.02.03
also: H02.03
Configuration error: the configuration number is unknown or incorrectCall a professional
H.02.04
also: H02.04
Parameter error: the factory settings are not in orderCall a professional
H.02.05
also: H02.05
The settings memory (CSU) does not match the control type (CU)Call a professional
H.02.09
also: H02.09
Partial blocking: the blocking input is active (frost protection keeps working)Call a professional
H.02.10
also: H02.10
Full blocking: the blocking input is active (without frost protection)Call a professional
H.02.12
also: H02.12
The enable signal from the external control did not arrive in time (waiting time expired)Call a professional
H.02.70
also: H02.70
The test of the external heat recovery unit has failedCall a professional
H.03.01
also: H03.01
No valid data received from the control (communication error with the CU-GH)Call a professional
H.03.02
also: H03.02
The measured ionisation current is too low: flame failure during operationDIY checks first
H.03.05
also: H03.05
Internal blocking in the gas valve control (fault in the safety core)Call a professional
H.03.17
also: H03.17
The periodic safety check is being carried outDIY checks first