Remeha Boiler Error Code E.00.07

DIY checks firstReviewed November 2026Checked against manufacturer documentation
What this code means
E.00.07: The difference between the return temperature and the flow temperature is too large

With E.00.07 the flow and return temperatures drift too far apart, almost always because of too little flow. Bleeding and topping up is the first thing you can do yourself; after that an installer must check the pump, the heat exchanger and the sensors.

Also shown as: E00.07

Applies to: Remeha Ace platform (Tzerra Ace, Calenta Ace, Avanta Ace)

Fix level
DIY checks first
Start with the checks on this page. Testing or replacing a part is usually a technician job.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Circulation pump, Return temperature sensor
Parts are model-specific; see the note below before ordering.

Common causes

  1. No flow: air in the system, low water pressure or a pump that is not working properly
  2. Fouled heat exchanger
  3. Sensor not connected, badly connected or faulty

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Check the water pressure and top up to about 1.5 to 2 bar if needed.
  2. Bleed the system and open the radiator valves.
  3. Reset the boiler once; if the code returns, call an installer.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

Most cases are solved by the checks above. Book a technician if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code E.00.07, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Parts that may be involved

Circulation pumpReturn temperature sensor

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about E.00.07

What does E.00.07 mean on a Remeha boiler?

E.00.07 means: The difference between the return temperature and the flow temperature is too large. With E.00.07 the flow and return temperatures drift too far apart, almost always because of too little flow. Bleeding and topping up is the first thing you can do yourself; after that an installer must check the pump, the heat exchanger and the sensors.

Can I fix Remeha E.00.07 myself?

Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.

How do I clear Remeha E.00.07?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Remeha boiler codes

See all Remeha boiler error codes