Home › Nefit error codes › Boiler › Error code 8U 365

Nefit Boiler Error Code 8U 365

Call a professionalReviewed November 2026Checked against manufacturer documentation
What this code means
8U 365: The leak test carried out on the gas valve has failed

Code 8U 365 has the same meaning as 8U 364: the automatic leak test of the gas valve has failed. The boiler no longer trusts the sealing of the gas control block. Leave the boiler off and have an installer check the gas block; this is not a fault to work on yourself.

Also shown as: 8U

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Gas control block
Parts are model-specific; see the note below before ordering.

Common causes

  1. Gas control block leaks through internally or does not close properly
  2. Poor contact in the wiring of the gas control block
  3. Gas control block faulty

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Note the full code and do not reset the boiler repeatedly.
  2. If in doubt, close the gas tap at the boiler and do not use the boiler.
  3. Call a CO-certified installer straight away; a failed gas valve leak test is always work on the gas side.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a Nefit boiler. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 8U 365, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

Gas control block

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 8U 365

What does 8U 365 mean on a Nefit boiler?

8U 365 means: The leak test carried out on the gas valve has failed. Code 8U 365 has the same meaning as 8U 364: the automatic leak test of the gas valve has failed. The boiler no longer trusts the sealing of the gas control block. Leave the boiler off and have an installer check the gas block; this is not a fault to work on yourself.

Can I fix Nefit 8U 365 myself?

Only the preliminary checks. Code 8U 365 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear Nefit 8U 365?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Nefit boiler codes

See all Nefit boiler error codes