Home › Nefit error codes

Nefit Error Codes

Every Nefit code in the database, by appliance. Open a code for its causes, the checks to run in order, and how to clear it.

Boilers · 80 codes

Nefit Boilers

CodeMeaningFix level
0Y 276
also: 0Y
The flow temperature sensor has measured a temperature above 95 °CDIY checks first
0Y 277
also: 0Y
The safety temperature sensor has measured a temperature above 95 °CDIY checks first
0Y 285
also: 0Y
The return temperature sensor has measured a temperature above 95 °CDIY checks first
2C 348
also: 2C
During hot water operation the flow temperature is above 85 °CDIY checks first
2E 207
also: 2E
The heating water pressure is too low (below 0.2 bar)DIY-friendly
2F 260
also: 2F
The flow temperature sensor measures no temperature rise after a burner startDIY checks first
2F 271
also: 2F
The temperature difference between the flow and safety temperature sensors is too largeDIY checks first
2F 345
also: 2F
The flow temperature sensor measures no temperature rise after a burner startDIY checks first
2L 266
also: 2L
The pump test has failed: the pressure sensor sees the pump build up no pressureDIY checks first
2L 329
also: 2L
The pressure sensor measures no water flowDIY checks first
2P 212
also: 2P
The temperature measured by the flow or safety temperature sensor rises too quicklyDIY checks first
2U 213
also: 2U
The measured temperature difference between the flow and return temperature sensors is too largeDIY checks first
2U 349
also: 2U
The temperature difference between the flow and return sensors measured at low load is too largeDIY checks first
2Y 281
also: 2Y
The pump is stuck or is running in airDIY checks first
2Y 282
also: 2Y
The control signal to the pump is missingCall a professional
3A 264
also: 3A
The fan control signal or supply voltage dropped out during operationCall a professional
3C 217
also: 3C
The fan runs irregularly during start-upCall a professional
3L 214
also: 3L
The fan does not run during the start-up phaseCall a professional
3P 216
also: 3P
The fan runs too slowlyCall a professional
3Y 215
also: 3Y
The fan runs too fastCall a professional
4A 218
also: 4A
The flow temperature sensor has measured a temperature above 105 °CCall a professional
4A 332
also: 4A
The flow temperature sensor has measured a temperature above 105 °CCall a professional
4C 224
also: 4C
An appliance thermostat (maximum or burner thermostat) has measured too high a temperature and is openCall a professional
4E 278
also: 4E
The boiler's sensor test has failedCall a professional
4E 347
also: 4E
The return temperature sensor has measured a higher heating water temperature than the flow temperature sensor; a restart follows after 10 minutesDIY checks first
4E 375
also: 4E
The contacts of the external sensor (for example a solar sensor) are short-circuitedCall a professional
4E 376
also: 4E
The contacts of the external sensor (for example a solar sensor) are interruptedCall a professional
4F 219
also: 4F
The safety temperature sensor has measured a temperature above 105 °CCall a professional
4L 220
also: 4L
The contacts of the safety temperature sensor are short-circuited, or the sensor has measured a temperature above 130 °CCall a professional
4P 221
also: 4P
The contacts of the safety temperature sensor are interruptedCall a professional
4U 222
also: 4U
The contacts of the flow temperature sensor are short-circuitedCall a professional
4Y 223
also: 4Y
The contacts of the flow temperature sensor are interruptedCall a professional
6A 227
also: 6A
Insufficient ionisation current was measured after the burner ignited: the boiler does not see a proper flameCall a professional
6C 306
also: 6C
An ionisation current was measured after the burner had gone out: the boiler still sees a flame that should not be thereCall a professional
6L 229
also: 6L
Insufficient ionisation current was measured while burning: the flame drops out or is not seen properlyCall a professional
7C 231
also: 7C
The mains voltage was interrupted during a locking faultDIY checks first
7H 328
also: 7H
There has been a brief interruption of the mains voltageDIY checks first
7L 261
also: 7L
The burner control unit is faultyCall a professional
7L 280
also: 7L
The burner control unit is faultyCall a professional
8U 364
also: 8U
The leak test carried out on the gas valve has failedCall a professional
8U 365
also: 8U
The leak test carried out on the gas valve has failedCall a professional
8Y 232
also: 8Y
The external switching contact is openDIY checks first
9A 235
also: 9A
The KIM is too new for the burner control unitCall a professional
9H 237
also: 9H
The burner control unit or the KIM is faultyCall a professional
9H 272
also: 9H
The burner control unit or the KIM is faultyCall a professional
9L 234
also: 9L
The contacts of the gas control block are interruptedCall a professional
9L 238
also: 9L
The burner control unit or the KIM is faultyCall a professional
9P 239
also: 9P
The burner control unit or the KIM is faultyCall a professional
9U 233
also: 9U
The burner control unit or the KIM is faultyCall a professional
C0 288
also: C0
The water pressure is too high, or the contacts of the pressure sensor are interruptedCall a professional
C0 289
also: C0
The contacts of the pressure sensor are short-circuitedCall a professional
CA 286
also: CA
The return temperature sensor has measured a return temperature above 105 °CCall a professional
CU 240
also: CU
The contacts of the return temperature sensor are short-circuitedCall a professional
CY 241
also: CY
The contacts of the return temperature sensor are interruptedCall a professional
E1 242
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 243
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 244
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 245
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 247
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 248
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 249
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 255
also: E1
The burner control unit or the KIM is faultyCall a professional
E1 257
also: E1
The burner control unit or the KIM is faultyCall a professional
EA 246
also: EA
The burner control unit or the KIM is faultyCall a professional
EA 252
also: EA
The burner control unit or the KIM is faultyCall a professional
EA 253
also: EA
The burner control unit or the KIM is faultyCall a professional
EC 251
also: EC
The burner control unit or the KIM is faultyCall a professional
EC 256
also: EC
The burner control unit or the KIM is faultyCall a professional
EF 254
also: EF
The burner control unit or the KIM is faultyCall a professional
EH 250
also: EH
The burner control unit or the KIM is faultyCall a professional
EH 258
also: EH
The burner control unit or the KIM is faultyCall a professional
EH 262
also: EH
The burner control unit or the KIM is faultyCall a professional
EL 259
also: EL
The burner control unit or the KIM is faultyCall a professional
EL 279
also: EL
The burner control unit or the KIM is faultyCall a professional
EL 290
also: EL
The burner control unit or the KIM is faultyCall a professional
EY 263
also: EY
The burner control unit or the KIM is faultyCall a professional
H07The measured heating water pressure is too low; the output for heating and hot water operation is limitedDIY-friendly
H11The hot water outlet temperature sensor is faulty; its function is taken over by the boiler softwareCall a professional
H13The set maintenance period has expired; maintenance is dueNot a fault
H25The contacts of the pressure sensor are interruptedCall a professional

More appliance types are being added. Codes vary by model and region.