Home › Nefit error codes › Boiler › Error code H13

Nefit Boiler Error Code H13

Not a faultReviewed November 2026Checked against manufacturer documentation
What this code means
H13: The set maintenance period has expired; maintenance is due

Message H13 is not a fault: the boiler indicates that the set maintenance period has passed. The appliance keeps working as normal, but a service is now really due. Regular maintenance prevents exactly the faults in this list, such as ignition codes 6A and 6L.

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
Not a fault
This is a status display, not a fault. No repair is needed.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Maintenance kit
Parts are model-specific; see the note below before ordering.

Common causes

  1. The set period since the last service has passed
  2. The maintenance counter was not reset, or was reset again, after the previous service

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Make an appointment for maintenance with a CO-certified company.
  2. In the meantime, check the water pressure and top up to 1.5 to 2 bar if needed.
  3. Note the message for the engineer; after the service he resets the period.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

This display is not a fault, so there is normally nothing to book. Call a technician only if the machine also behaves abnormally, or if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code H13, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Parts that may be involved

Maintenance kit

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about H13

What does H13 mean on a Nefit boiler?

H13 means: The set maintenance period has expired; maintenance is due. Message H13 is not a fault: the boiler indicates that the set maintenance period has passed. The appliance keeps working as normal, but a service is now really due. Regular maintenance prevents exactly the faults in this list, such as ignition codes 6A and 6L.

Can I fix Nefit H13 myself?

There is nothing to fix: code H13 is a status display, not a fault. The checks on this page show how to exit the mode or confirm the setting.

How do I clear Nefit H13?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.