Nefit Boiler Error Code 6A 227

Call a professionalReviewed November 2026Checked against manufacturer documentation
What this code means
6A 227: Insufficient ionisation current was measured after the burner ignited: the boiler does not see a proper flame

Code 6A 227 is Nefit's best-known ignition fault: the burner ignites, but the boiler measures too little ionisation current and so does not see a reliable flame. First check that there is gas and reset once. In most cases the ignition unit or ionisation electrode is dirty or worn, or the siphon is blocked; an installer fixes that during a service.

Also shown as: 6A

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 20–40 minutes
For the 4 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Ionisation electrode, Ignition unit
Parts are model-specific; see the note below before ordering.

Common causes

  1. Gas tap (partly) closed or no gas supply
  2. Ignition unit or ionisation electrode dirty, worn or damaged
  3. Blocked condensate trap (siphon), so the burner does not burn properly
  4. Wrong gas-air ratio because maintenance is overdue

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Check that the gas tap at the boiler and the main tap are open and that other gas appliances work.
  2. Check the water pressure and top up if needed; then press the reset button once.
  3. If the boiler still does not ignite, do not keep resetting but call a CO-certified installer.
  4. If you smell gas, close the main tap, ventilate and call the grid operator or an installer; do not ignite anything.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a Nefit boiler. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 6A 227, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

Ionisation electrodeIgnition unit

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 6A 227

What does 6A 227 mean on a Nefit boiler?

6A 227 means: Insufficient ionisation current was measured after the burner ignited: the boiler does not see a proper flame. Code 6A 227 is Nefit's best-known ignition fault: the burner ignites, but the boiler measures too little ionisation current and so does not see a reliable flame. First check that there is gas and reset once. In most cases the ignition unit or ionisation electrode is dirty or worn, or the siphon is blocked; an installer fixes that during a service.

Can I fix Nefit 6A 227 myself?

Only the preliminary checks. Code 6A 227 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear Nefit 6A 227?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Nefit boiler codes