Nefit Boiler Error Code 2U 349

DIY checks firstReviewed November 2026Checked against manufacturer documentation
What this code means
2U 349: The temperature difference between the flow and return sensors measured at low load is too large

Code 2U 349 is the low-load variant of 2U 213: even at low output the difference between flow and return becomes too large. The cause is almost always the flow: too little water going round, air in the pipes or too many closed valves. After bleeding and topping up the code usually disappears; otherwise it is a job for an installer.

Also shown as: 2U

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
DIY checks first
Start with the checks on this page. Testing or replacing a part is usually a technician job.
Time to run the checks
About 20–40 minutes
For the 4 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Circulation pump, Flow temperature sensor (+1 more below)
Parts are model-specific; see the note below before ordering.

Common causes

  1. Too little flow at low output
  2. Air in the system
  3. Almost all radiators are closed

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Check the water pressure and top up to 1.5 to 2 bar if needed.
  2. Open all radiator valves and bleed the radiators and the boiler.
  3. Press the reset button once and see whether the code stays away.
  4. If the code returns, call a CO-certified installer.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

Most cases are solved by the checks above. Book a technician if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 2U 349, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Parts that may be involved

Circulation pumpFlow temperature sensorReturn temperature sensor

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 2U 349

What does 2U 349 mean on a Nefit boiler?

2U 349 means: The temperature difference between the flow and return sensors measured at low load is too large. Code 2U 349 is the low-load variant of 2U 213: even at low output the difference between flow and return becomes too large. The cause is almost always the flow: too little water going round, air in the pipes or too many closed valves. After bleeding and topping up the code usually disappears; otherwise it is a job for an installer.

Can I fix Nefit 2U 349 myself?

Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.

How do I clear Nefit 2U 349?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.