Nefit Boiler Error Code 2U 213
Code 2U 213 means the difference between flow and return temperature is becoming too large. That happens when the water circulates too slowly: the boiler then supplies much hotter water than comes back. Opening valves, bleeding and checking the pressure often helps. If the difference stays too large, an installer must look at the pump and the sensors.
Also shown as: 2U
Applies to: Nefit ProLine and TrendLine condensing boilers
Common causes
- Too little flow, so the water loses or holds too much heat on its way round
- Air in the system
- Almost all radiators are closed or the bypass is set incorrectly
What to check, in order
- Check the water pressure and top up to 1.5 to 2 bar if needed.
- Open all radiator valves and bleed the radiators and the boiler.
- Press the reset button once and see whether the code stays away.
- If the code returns, call a CO-certified installer; the flow and both sensors need to be checked.
Clear the code and test
- Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
- Make sure the boiler has power and the gas tap at the boiler is open.
- If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
- Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.
When to call a professional
Most cases are solved by the checks above. Book a technician if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code 2U 213, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.
Parts that may be involved
Circulation pumpFlow temperature sensorReturn temperature sensor
Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.
Questions people ask about 2U 213
What does 2U 213 mean on a Nefit boiler?
2U 213 means: The measured temperature difference between the flow and return temperature sensors is too large. Code 2U 213 means the difference between flow and return temperature is becoming too large. That happens when the water circulates too slowly: the boiler then supplies much hotter water than comes back. Opening valves, bleeding and checking the pressure often helps. If the difference stays too large, an installer must look at the pump and the sensors.
Can I fix Nefit 2U 213 myself?
Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.
How do I clear Nefit 2U 213?
Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
Sources checked
The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.