Nefit Boiler Error Code 2F 345

DIY checks firstReviewed November 2026Checked against manufacturer documentation
What this code means
2F 345: The flow temperature sensor measures no temperature rise after a burner start

Code 2F 345 has the same meaning as 2F 260: after a burner start the flow sensor does not see the temperature rise. The burner fires, but the water barely moves, for example because of air in the boiler or a stopped pump. Top up and bleed first; if it returns, an installer must check the pump.

Also shown as: 2F

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
DIY checks first
Start with the checks on this page. Testing or replacing a part is usually a technician job.
Time to run the checks
About 20–40 minutes
For the 4 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Circulation pump, Flow temperature sensor
Parts are model-specific; see the note below before ordering.

Common causes

  1. Air in the boiler or the system, so there is no flow
  2. Circulation pump not running, so the heat stays at the burner
  3. Water pressure too low

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Check the water pressure and top up to 1.5 to 2 bar if needed.
  2. Bleed the radiators and the boiler and open all radiator valves.
  3. Press the reset button once and see whether the boiler now heats up.
  4. If the code returns, call a CO-certified installer; the pump and sensor need to be measured.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

Most cases are solved by the checks above. Book a technician if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 2F 345, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Parts that may be involved

Circulation pumpFlow temperature sensor

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 2F 345

What does 2F 345 mean on a Nefit boiler?

2F 345 means: The flow temperature sensor measures no temperature rise after a burner start. Code 2F 345 has the same meaning as 2F 260: after a burner start the flow sensor does not see the temperature rise. The burner fires, but the water barely moves, for example because of air in the boiler or a stopped pump. Top up and bleed first; if it returns, an installer must check the pump.

Can I fix Nefit 2F 345 myself?

Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.

How do I clear Nefit 2F 345?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.