Nefit Boiler Error Code 2C 348
Code 2C 348 appears while drawing hot water: the flow temperature then rises above 85 °C. The boiler interrupts hot water operation to prevent overheating. Air, low pressure or a weak pump are the usual causes. After topping up and bleeding it often works again; if the code keeps coming, an installer must check the pump and the sensor.
Also shown as: 2C
Applies to: Nefit ProLine and TrendLine condensing boilers
Common causes
- Air in the heating system during hot water operation
- Water pressure too low or too little flow
- Circulation pump not running properly
What to check, in order
- Check the water pressure on the display or pressure gauge and top up to 1.5 to 2 bar if needed.
- Bleed the radiators and the boiler.
- Press the reset button once and then test the hot water again.
- If the code returns, call a CO-certified installer.
Clear the code and test
- Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
- Make sure the boiler has power and the gas tap at the boiler is open.
- If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
- Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.
When to call a professional
Most cases are solved by the checks above. Book a technician if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code 2C 348, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.
Parts that may be involved
Circulation pumpFlow temperature sensor
Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.
Questions people ask about 2C 348
What does 2C 348 mean on a Nefit boiler?
2C 348 means: During hot water operation the flow temperature is above 85 °C. Code 2C 348 appears while drawing hot water: the flow temperature then rises above 85 °C. The boiler interrupts hot water operation to prevent overheating. Air, low pressure or a weak pump are the usual causes. After topping up and bleeding it often works again; if the code keeps coming, an installer must check the pump and the sensor.
Can I fix Nefit 2C 348 myself?
Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.
How do I clear Nefit 2C 348?
Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.