Home › LG error codes › Air Conditioner › Error code CH22

LG Air Conditioner Error Code CH22

Call a professionalReviewed November 2026Checked against manufacturer documentation
What this code means
CH22: Input current too high (CT2 max current)

The unit measured its incoming current above the safe limit and stopped. Dirty coils and blocked airflow can overload the compressor enough to trigger it, so clean those first; the electrical testing that follows is professional work.

Also shown as: 22

Applies to: Residential wall-split and multi-split systems

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 20–40 minutes
For the 4 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Compressor, Outdoor control board
Parts are model-specific; see the note below before ordering.

Common causes

  1. Compressor drawing excessive current
  2. Outdoor coil dirty or airflow blocked, overloading the compressor
  3. Supply voltage too low, raising the current draw
  4. Inverter board fault

What to check, in order

Safety first. Switch the unit off at the breaker before checking anything. Never open the refrigerant circuit or the electrical boxes of the indoor or outdoor unit — refrigerant work is licensed work. The checks on this page stay on the outside: power, filters, remote control and airflow.
  1. Check the outdoor unit and clear away anything blocking the fan or coil: leaves, covers, boxes, or a fence panel fitted too close.
  2. Clean the indoor air filters, let them dry completely, and refit them.
  3. Switch the power off at the breaker for five minutes, restart once, and note whether the code returns while the unit is working hard.
  4. If it returns, stop restarting it and call a technician: the compressor and current sensing need testing.

Clear the code and test

  1. Fix what the checks above found first — a filter cleaned, an obstruction removed, the breaker restored. Clearing the code without fixing the cause only brings it back.
  2. Restore power at the breaker and switch the unit on with the remote.
  3. Run the unit in cooling or heating for ten to fifteen minutes and watch whether the code returns; some codes only appear after the compressor has run for a while.
  4. If the unit runs with no code, the fault is cleared. If the code returns, write down the code and whether the indoor or outdoor unit shows it before calling a technician — it speeds up the diagnosis.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a LG air conditioner. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code CH22, your model number (on a label on the side of the indoor unit) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

CompressorOutdoor control board

Parts are model-specific. Find your model number first — usually on a label on the side of the indoor unit — and match the part to that number before ordering.

Questions people ask about CH22

What does CH22 mean on a LG air conditioner?

CH22 means: Input current too high (CT2 max current). The unit measured its incoming current above the safe limit and stopped. Dirty coils and blocked airflow can overload the compressor enough to trigger it, so clean those first; the electrical testing that follows is professional work.

Can I fix LG CH22 myself?

Only the preliminary checks. Code CH22 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear LG CH22?

Fix what the checks above found first — a filter cleaned, an obstruction removed, the breaker restored. Clearing the code without fixing the cause only brings it back. Restore power at the breaker and switch the unit on with the remote. Run the unit in cooling or heating for ten to fifteen minutes and watch whether the code returns; some codes only appear after the compressor has run for a while.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other LG air conditioner codes

See all LG air conditioner error codes