Home › Itho Daalderop error codes › Heat Pump › Error code A1 31

Itho Daalderop Heat Pump Error Code A1 31

Call a professionalReviewed November 2026Checked against manufacturer documentation
What this code means
A1 31: The discharge-gas temperature (sensor T6) is too high

An excessive discharge-gas temperature puts heavy load on the compressor and points to excessive pressure in the refrigerant circuit or too little refrigerant. Measuring with a manifold set and hunting for leaks is specialist work on the sealed circuit.

Also shown as: A01 31

Applies to: Itho Daalderop WPU 5G and older WPU types with an MFT thermostat (shown there as A01)

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Temperature sensor T6 (discharge gas), Compressor
Parts are model-specific; see the note below before ordering.

Common causes

  1. Excessive pressure in the refrigerant circuit, for example due to too little flow on the condenser side
  2. Too little refrigerant in the circuit, for example due to a leak
  3. Sensor T6 reads incorrectly due to a fault and passes on a temperature that is too high

What to check, in order

Safety first. Switch the heat pump off at the breaker before checking anything. Never open the refrigerant circuit or the electrical boxes — refrigerant work requires F-gas certification. The checks on this page stay on the outside: power, settings, filters and pressure where your manual allows it.
  1. Open all radiator valves and underfloor-heating groups, bleed the heating system and check the water pressure (1.5 to 2 bar).
  2. Then let the unit cool down, reset it once and see whether the code stays away.
  3. If the code returns, call an installer with F-gas certification and quote the code; the circuit pressures must be measured with a manifold gauge set and the circuit checked for leaks.

Clear the code and test

  1. Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back.
  2. Make sure the heat pump has power and the controller is set to heating or hot water, as you need it.
  3. Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.
  4. If the unit runs a full cycle with no code, the fault is cleared. If the code returns, write down the code and what the unit was doing (heating, hot water or defrosting) before calling a technician — it speeds up the diagnosis.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a Itho Daalderop heat pump. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code A1 31, your model number (on a label on the type plate, usually on the side of the unit) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

Temperature sensor T6 (discharge gas)Compressor

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually on the side of the unit — and match the part to that number before ordering.

Questions people ask about A1 31

What does A1 31 mean on a Itho Daalderop heat pump?

A1 31 means: The discharge-gas temperature (sensor T6) is too high. An excessive discharge-gas temperature puts heavy load on the compressor and points to excessive pressure in the refrigerant circuit or too little refrigerant. Measuring with a manifold set and hunting for leaks is specialist work on the sealed circuit.

Can I fix Itho Daalderop A1 31 myself?

Only the preliminary checks. Code A1 31 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear Itho Daalderop A1 31?

Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back. Make sure the heat pump has power and the controller is set to heating or hot water, as you need it. Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Itho Daalderop heat pump codes

See all Itho Daalderop heat pump error codes