Itho Daalderop Heat Pump Error Codes

Every Itho Daalderop Heat Pump code in the database, with its meaning. Open a code for its causes, the checks to run in order, and how to clear it.

CodeMeaningFix level
A1 1
also: A01 1
Temperature sensor T1 (outdoor) is faulty or reads outside the normal operating rangeCall a professional
A1 10
also: A01 10
Temperature sensor T11 (heating return) is faulty or reads outside the normal operating rangeCall a professional
A1 11
also: A01 11
Temperature sensor T10 (heating flow) is faulty or reads outside the normal operating rangeCall a professional
A1 12
also: A01 12
The pressure sensor of the heating circuit passes on no usable readingCall a professional
A1 13
also: A01 13
Current measuring coil 1 is not working properly or is faultyCall a professional
A1 14
also: A01 14
Current measuring coil 2 is not working properly or is faultyCall a professional
A1 15The flow sensor of the source circuit is not working properly or is faultyCall a professional
A1 16
also: A01 16
An automatic function or setting has been switched to manual operationNot a fault
A1 17
also: A01 17
The high-pressure switch (pressostat) in the refrigerant circuit has trippedCall a professional
A1 18
also: A01 18
The high-pressure switch (pressostat) is not working properly or is faultyCall a professional
A1 19
also: A01 19
The water pressure of the heating system is too low; the heat pump does not work until the pressure is restoredDIY checks first
A1 2
also: A01 2
Temperature sensor T3 (storage vessel, low) is faulty or reads outside the normal operating rangeCall a professional
A1 20
also: A01 20
The water pressure of the heating system is low; the heat pump does keep workingDIY-friendly
A1 21Compressor protection tripped: the compressor starting current is too high or the temperature protection is not working properlyCall a professional
A1 22The phase sequence in the wall socket is not clockwise (right-rotating)Call a professional
A1 23There is no clockwise rotating field on the incoming 3-phase supply of the heat pumpCall a professional
A1 24
also: A01 24
The current draw of the compressor is too lowCall a professional
A1 25
also: A01 25
The current draw of the electric heating element is too lowCall a professional
A1 26
also: A01 26
The current draw of the compressor is too highCall a professional
A1 27
also: A01 27
The current draw of the electric heating element is too highCall a professional
A1 28
also: A01 28
The source return temperature (sensor T8) is too lowCall a professional
A1 29
also: A01 29
The source supply temperature (sensor T9) is too lowCall a professional
A1 3
also: A01 3
Temperature sensor T2 (storage vessel, high) is faulty or reads outside the normal operating rangeCall a professional
A1 30
also: A01 30
The liquid temperature (sensor T7) is too highCall a professional
A1 31
also: A01 31
The discharge-gas temperature (sensor T6) is too highCall a professional
A1 32
also: A01 32
The injection temperature (sensor T4) is too lowCall a professional
A1 33
also: A01 33
The discharge-gas temperature is too high relative to the liquid temperature and the expansion valve is fully openCall a professional
A1 34The heating flow temperature (sensor T10) is too highDIY checks first
A1 36There is a communication fault between the heat pump and the room thermostatDIY checks first
A1 37The compressor draws current without being drivenCall a professional
A1 38The relay of the electric heating element sticksCall a professional
A1 4
also: A01 4
Temperature sensor T4 (injection) is faulty or reads outside the normal operating rangeCall a professional
A1 42Temperature sensors T8 (source return) and T9 (source supply) are not working properly or are faultyCall a professional
A1 43An unsuitable thermostat has been connected to the heat pumpCall a professional
A1 5
also: A01 5
Temperature sensor T5 (suction gas) is faulty or reads outside the normal operating rangeCall a professional
A1 6
also: A01 6
Temperature sensor T6 (discharge gas) is faulty or reads outside the normal operating rangeCall a professional
A1 7
also: A01 7
Temperature sensor T7 (liquid) is faulty or reads outside the normal operating rangeCall a professional
A1 8
also: A01 8
Temperature sensor T8 (source return) is faulty or reads outside the normal operating rangeCall a professional
A1 9
also: A01 9
Temperature sensor T9 (source supply) is faulty or reads outside the normal operating rangeCall a professional