Heat Pumps Error Codes
Fault codes for heat pumps from every brand in the database, with the meaning of each code. Choose your brand for the full list with fix levels, or open a code directly.
Itho Daalderop Heat Pumps
39 codes · Itho Daalderop Heat Pump Error Codes: Full List
Itho Daalderop A1 1Temperature sensor T1 (outdoor) is faulty or reads outside the normal operating rangeItho Daalderop A1 10Temperature sensor T11 (heating return) is faulty or reads outside the normal operating rangeItho Daalderop A1 11Temperature sensor T10 (heating flow) is faulty or reads outside the normal operating rangeItho Daalderop A1 12The pressure sensor of the heating circuit passes on no usable readingItho Daalderop A1 13Current measuring coil 1 is not working properly or is faultyItho Daalderop A1 14Current measuring coil 2 is not working properly or is faultyItho Daalderop A1 15The flow sensor of the source circuit is not working properly or is faultyItho Daalderop A1 16An automatic function or setting has been switched to manual operationItho Daalderop A1 17The high-pressure switch (pressostat) in the refrigerant circuit has trippedItho Daalderop A1 18The high-pressure switch (pressostat) is not working properly or is faultyItho Daalderop A1 19The water pressure of the heating system is too low; the heat pump does not work until the pressure is restoredItho Daalderop A1 2Temperature sensor T3 (storage vessel, low) is faulty or reads outside the normal operating rangeItho Daalderop A1 20The water pressure of the heating system is low; the heat pump does keep workingItho Daalderop A1 21Compressor protection tripped: the compressor starting current is too high or the temperature protection is not working properlyItho Daalderop A1 22The phase sequence in the wall socket is not clockwise (right-rotating)Itho Daalderop A1 23There is no clockwise rotating field on the incoming 3-phase supply of the heat pumpItho Daalderop A1 24The current draw of the compressor is too lowItho Daalderop A1 25The current draw of the electric heating element is too lowItho Daalderop A1 26The current draw of the compressor is too highItho Daalderop A1 27The current draw of the electric heating element is too highItho Daalderop A1 28The source return temperature (sensor T8) is too lowItho Daalderop A1 29The source supply temperature (sensor T9) is too lowItho Daalderop A1 3Temperature sensor T2 (storage vessel, high) is faulty or reads outside the normal operating rangeItho Daalderop A1 30The liquid temperature (sensor T7) is too highItho Daalderop A1 31The discharge-gas temperature (sensor T6) is too highItho Daalderop A1 32The injection temperature (sensor T4) is too lowItho Daalderop A1 33The discharge-gas temperature is too high relative to the liquid temperature and the expansion valve is fully openItho Daalderop A1 34The heating flow temperature (sensor T10) is too highItho Daalderop A1 36There is a communication fault between the heat pump and the room thermostatItho Daalderop A1 37The compressor draws current without being drivenItho Daalderop A1 38The relay of the electric heating element sticksItho Daalderop A1 4Temperature sensor T4 (injection) is faulty or reads outside the normal operating rangeItho Daalderop A1 42Temperature sensors T8 (source return) and T9 (source supply) are not working properly or are faultyItho Daalderop A1 43An unsuitable thermostat has been connected to the heat pumpItho Daalderop A1 5Temperature sensor T5 (suction gas) is faulty or reads outside the normal operating rangeItho Daalderop A1 6Temperature sensor T6 (discharge gas) is faulty or reads outside the normal operating rangeItho Daalderop A1 7Temperature sensor T7 (liquid) is faulty or reads outside the normal operating rangeItho Daalderop A1 8Temperature sensor T8 (source return) is faulty or reads outside the normal operating rangeItho Daalderop A1 9Temperature sensor T9 (source supply) is faulty or reads outside the normal operating range