Itho Daalderop Heat Pump Error Code A1 23
With code 23 the heat pump measures no clockwise rotating field on its own incoming supply, while a 3-phase compressor needs one to run. The cause is in the feed: a wrong phase sequence or a missing phase. Repair means work on the electrical installation, so it is a job for an installer or electrician.
Applies to: Itho Daalderop WPU 5G (including WPU-I, WPU-C, WPU-E, WPU-GE, WPU-KC and WPU-COE 5G)
Common causes
- The phase sequence of the incoming supply is wrong, for example after work on the main connection or meter cupboard
- One of the three phases is missing or interrupted in the feed to the heat pump
What to check, in order
- Write down the code and check whether work was recently done on the electrical installation or the main connection; tell the installer.
- Check whether other 3-phase appliances and the rest of the home work normally; a missing phase is often noticeable elsewhere in the house too.
- Do not work on the meter cupboard or the supply yourself. Have an installer or electrician restore the phase sequence; the fix is usually swapping phases L2 and L3.
Clear the code and test
- Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back.
- Make sure the heat pump has power and the controller is set to heating or hot water, as you need it.
- Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.
- If the unit runs a full cycle with no code, the fault is cleared. If the code returns, write down the code and what the unit was doing (heating, hot water or defrosting) before calling a technician — it speeds up the diagnosis.
When to call a professional
This code usually points to a faulty part, wiring or the control board on a Itho Daalderop heat pump. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code A1 23, your model number (on a label on the type plate, usually on the side of the unit) and the checks you already ran. It shortens the visit.
Repair or replace?
This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.
Questions people ask about A1 23
What does A1 23 mean on a Itho Daalderop heat pump?
A1 23 means: There is no clockwise rotating field on the incoming 3-phase supply of the heat pump. With code 23 the heat pump measures no clockwise rotating field on its own incoming supply, while a 3-phase compressor needs one to run. The cause is in the feed: a wrong phase sequence or a missing phase. Repair means work on the electrical installation, so it is a job for an installer or electrician.
Can I fix Itho Daalderop A1 23 myself?
Only the preliminary checks. Code A1 23 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.
How do I clear Itho Daalderop A1 23?
Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back. Make sure the heat pump has power and the controller is set to heating or hot water, as you need it. Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.
Sources checked
- Itho Daalderop WPU 5G user manual (manufacturer document)
- Itho Daalderop service chapter: WPU 5G faults (JK Engineered Solutions)