Home › Intergas error codes › Boiler › Error code 5

Intergas Boiler Error Code 5

DIY checks firstReviewed November 2026Checked against manufacturer documentation
What this code means
5: Poor flame signal: the flame is not detected properly while burning

With code 5 the boiler does see a flame, but the signal is too weak or unstable. Causes include a blocked condensate drain, an incorrect gas adjustment or poor earthing. Check the gas supply and the flue outlet outside and reset once; after that it is a job for an installer.

Also shown as: 05

Applies to: Intergas HRE and Kombi Kompakt

Fix level
DIY checks first
Start with the checks on this page. Testing or replacing a part is usually a technician job.
Time to run the checks
About 20–40 minutes
For the 4 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Ignition/ionisation electrode, Gas valve (+1 more below)
Parts are model-specific; see the note below before ordering.

Common causes

  1. Blocked or frozen condensate drain
  2. Incorrect CO2 adjustment of the gas valve
  3. Poor earthing of the ionisation electrode or the boiler
  4. Flue gas being drawn back into the flue (back draught or recirculation)

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Check that the gas tap is fully open and that other gas appliances work normally.
  2. Check outside whether the flue outlet is clear of leaves, nests or ice, and clear the outlet if needed.
  3. Check that the boiler is plugged into an earthed socket and reset the boiler once.
  4. If the code returns, have an installer check the ionisation electrode, the condensate drain and the adjustment.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

Most cases are solved by the checks above. Book a technician if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 5, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Parts that may be involved

Ignition/ionisation electrodeGas valveCondensate drain

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 5

What does 5 mean on a Intergas boiler?

5 means: Poor flame signal: the flame is not detected properly while burning. With code 5 the boiler does see a flame, but the signal is too weak or unstable. Causes include a blocked condensate drain, an incorrect gas adjustment or poor earthing. Check the gas supply and the flue outlet outside and reset once; after that it is a job for an installer.

Can I fix Intergas 5 myself?

Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.

How do I clear Intergas 5?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Intergas boiler codes

See all Intergas boiler error codes