Home › Intergas error codes › Boiler › Error code 27

Intergas Boiler Error Code 27

Call a professionalReviewed November 2026Checked against manufacturer documentation
What this code means
27: Short circuit in the outdoor sensor (outside temperature sensor)

Code 27 means a short circuit in the outdoor sensor, the sensor that measures the outside temperature for weather-compensated control. The sensor or the wiring must be replaced by an installer.

Applies to: Intergas HRE and Kombi Kompakt

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Outdoor sensor
Parts are model-specific; see the note below before ordering.

Common causes

  1. Short circuit in the outdoor sensor; the measured resistance is too low (below 1 kΩ)
  2. Damaged wiring to the outdoor sensor

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Note the code; the heating often keeps working, but the weather-compensated control will not work properly.
  2. Check outside, as far as visible without opening anything, whether the cable of the outdoor sensor is damaged.
  3. Have an installer test the outdoor sensor and the wiring and replace them if needed.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a Intergas boiler. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 27, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

Outdoor sensor

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 27

What does 27 mean on a Intergas boiler?

27 means: Short circuit in the outdoor sensor (outside temperature sensor). Code 27 means a short circuit in the outdoor sensor, the sensor that measures the outside temperature for weather-compensated control. The sensor or the wiring must be replaced by an installer.

Can I fix Intergas 27 myself?

Only the preliminary checks. Code 27 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear Intergas 27?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Intergas boiler codes

See all Intergas boiler error codes