CodeMeaningFix level
1
also: 01
The boiler gets too hot: the heat cannot be carried away (insufficient flow)DIY checks first
10Flow sensor S1 is open circuit (no signal)DIY checks first
11Short circuit in flow sensor S1Call a professional
12Flow sensor S1 reads a sudden temperature drop of 10 °C within 1 secondCall a professional
13Flow sensor S1 reads a sudden temperature rise of 10 °C within 1 secondCall a professional
14Flow sensor S1 reads no temperature change while the boiler is operatingCall a professional
2
also: 02
Flow and return sensors (S1 and S2) are in the wrong location or swappedCall a professional
27Short circuit in the outdoor sensor (outside temperature sensor)Call a professional
29Gas valve relay fault (ignition module)Call a professional
30Gas valve relay fault (PCB or wiring to the gas valve)Call a professional
4
also: 04
No flame signal: the burner does not ignite or the flame is not detectedDIY checks first
5
also: 05
Poor flame signal: the flame is not detected properly while burningDIY checks first
6
also: 06
Flame detection fault: a flame is reported when there should be none (false flame)Call a professional
8
also: 08
Incorrect fan speed: the fan runs too slowlyCall a professional
F000Heat exchanger sensor S0 is faultyCall a professional
F001Temperature too high during central heating operationDIY checks first
F002Temperature too high during hot water operationCall a professional
F003Flue gas temperature too highCall a professional
F004No flame during start-upDIY checks first
F005Flame failure during operation: the flame drops out or the flame signal is too weakDIY checks first
F006Flame simulation: a flame is reported when there should be noneCall a professional
F007No or insufficient ionisation current: the flame is not detected properlyCall a professional
F009Internal fault in the burner control unitCall a professional
F010
also: F011
Sensor fault S0: the heat exchanger sensor does not read properlyCall a professional
F011
also: F010
Sensor fault S0: the heat exchanger sensor does not read properlyCall a professional
F012Sensor fault S5: the flue gas sensor does not read properlyCall a professional
F018Flue outlet and/or air inlet blockedDIY checks first
F019Fault in the BMM (burner management module)Call a professional
F027Short circuit in outdoor sensor S6Call a professional
F030Sensor fault S3: the hot water sensor does not read properlyCall a professional
F031Sensor fault S1: the heating flow sensor does not read properlyCall a professional