Home › Daikin error codes › Air Conditioner › Error code C5

Daikin Air Conditioner Error Code C5

Call a professionalReviewed November 2026Checked against manufacturer documentation
What this code means
C5: Indoor heat exchanger gas pipe thermistor fault

The second temperature sensor on the indoor coil, on the gas pipe side, has failed or lost contact. The unit stops because it can no longer control superheat safely.

Applies to: Residential split and multi-split systems

Fix level
Call a professional
The checks on this page are preliminary. The likely fix involves a part, wiring or the control board.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Gas pipe thermistor, Indoor unit PCB
Parts are model-specific; see the note below before ordering.

Common causes

  1. Defective gas pipe thermistor
  2. Defective indoor unit PCB
  3. Defective connector contact

What to check, in order

Safety first. Switch the unit off at the breaker before checking anything. Never open the refrigerant circuit or the electrical boxes of the indoor or outdoor unit — refrigerant work is licensed work. The checks on this page stay on the outside: power, filters, remote control and airflow.
  1. Switch the unit off at the breaker or isolator, wait five minutes, then switch it back on and run it again.
  2. There is no user-side test for a thermistor — beyond one reset, note the code and the model name for the engineer.
  3. If the code comes back after the reset, stop restarting the unit and book a Daikin service engineer — the faulty part has to be tested and replaced.

Clear the code and test

  1. Fix what the checks above found first — a filter cleaned, an obstruction removed, the breaker restored. Clearing the code without fixing the cause only brings it back.
  2. Restore power at the breaker and switch the unit on with the remote.
  3. Run the unit in cooling or heating for ten to fifteen minutes and watch whether the code returns; some codes only appear after the compressor has run for a while.
  4. If the unit runs with no code, the fault is cleared. If the code returns, write down the code and whether the indoor or outdoor unit shows it before calling a technician — it speeds up the diagnosis.

When to call a professional

This code usually points to a faulty part, wiring or the control board on a Daikin air conditioner. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code C5, your model number (on a label on the side of the indoor unit) and the checks you already ran. It shortens the visit.

Repair or replace?

This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.

Parts that may be involved

Gas pipe thermistorIndoor unit PCB

Parts are model-specific. Find your model number first — usually on a label on the side of the indoor unit — and match the part to that number before ordering.

Questions people ask about C5

What does C5 mean on a Daikin air conditioner?

C5 means: Indoor heat exchanger gas pipe thermistor fault. The second temperature sensor on the indoor coil, on the gas pipe side, has failed or lost contact. The unit stops because it can no longer control superheat safely.

Can I fix Daikin C5 myself?

Only the preliminary checks. Code C5 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.

How do I clear Daikin C5?

Fix what the checks above found first — a filter cleaned, an obstruction removed, the breaker restored. Clearing the code without fixing the cause only brings it back. Restore power at the breaker and switch the unit on with the remote. Run the unit in cooling or heating for ten to fifteen minutes and watch whether the code returns; some codes only appear after the compressor has run for a while.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Daikin air conditioner codes

See all Daikin air conditioner error codes