CodeMeaningFix level
A0External protection device has activatedCall a professional
A1Indoor unit control board faultCall a professional
A3Drain water level is too highDIY checks first
A5Freeze-up protection in cooling, high-pressure control in heatingDIY checks first
A6Indoor fan motor faultCall a professional
A7Swing flap (louvre) motor faultDIY checks first
A9Electronic expansion valve fault (indoor unit)Call a professional
AHAir cleaner dust collector faultDIY checks first
C4Indoor heat exchanger liquid pipe thermistor faultCall a professional
C5Indoor heat exchanger gas pipe thermistor faultCall a professional
C7Front panel drive motor faultDIY checks first
C9Indoor suction air thermistor faultCall a professional
CCHumidity sensor faultCall a professional
E0Outdoor unit protection device has activatedCall a professional
E1Outdoor unit control board faultCall a professional
E3High pressure switch has activatedDIY checks first
E4Low pressure switch has activatedCall a professional
E5Inverter compressor motor lock or overheatCall a professional
E6Standard compressor motor overcurrent or lockCall a professional
E7Outdoor fan motor faultDIY checks first
E8Inverter compressor overcurrentCall a professional
E9Electronic expansion valve coil fault (outdoor unit)Call a professional
EAFour-way valve or cool/heat switching faultCall a professional
F3Discharge pipe temperature faultCall a professional
F6Abnormal high pressure or refrigerant overchargedCall a professional
H0Compressor sensor system faultCall a professional
H3High pressure switch faultCall a professional
H6Compressor position detection sensor faultCall a professional
H7Outdoor fan motor signal faultCall a professional
H8Compressor input current (CT) system faultCall a professional
H9Outdoor air thermistor faultCall a professional
J3Discharge pipe thermistor faultCall a professional
J5Suction pipe thermistor faultCall a professional
J6Outdoor heat exchanger thermistor faultCall a professional
L3Electrical component box overheatingDIY checks first
L4Inverter cooling fin overheatingDIY checks first
L5Inverter instantaneous overcurrent (DC output)Call a professional
L8Inverter compressor overcurrent (overload)Call a professional
L9Inverter compressor start-up errorCall a professional
P4Inverter cooling fin temperature sensor faultCall a professional
PJOutdoor unit capacity setting faultCall a professional
U0Shortage of refrigerantCall a professional
U2Power supply fault or momentary power failureDIY checks first
U4Indoor–outdoor transmission (communication) errorDIY checks first
U5Indoor unit–remote controller transmission errorCall a professional
U8Main–sub remote controller transmission errorCall a professional
UAImproper combination of indoor and outdoor unitsCall a professional
UFSystem setup not completedCall a professional
UHSystem fault (transmission wiring or indoor board)Call a professional