Home › Daikin error codes › Air Conditioner › Error code A3

Daikin Air Conditioner Error Code A3

DIY checks firstReviewed November 2026Checked against manufacturer documentation
What this code means
A3: Drain water level is too high

Condensate water is not draining away, so the float switch has stopped the unit before it overflows. A blocked or badly sloped drain is the most common cause; on units with a built-in pump, the pump or float switch may have failed.

Applies to: Residential split and multi-split systems

Fix level
DIY checks first
Start with the checks on this page. Testing or replacing a part is usually a technician job.
Time to run the checks
About 15–30 minutes
For the 3 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Drain pump, Float switch (+1 more below)
Parts are model-specific; see the note below before ordering.

Common causes

  1. Drain pipe clogged, or running uphill so water cannot flow away
  2. Defective drain pump
  3. Defective float switch, or a short in its connector

What to check, in order

Safety first. Switch the unit off at the breaker before checking anything. Never open the refrigerant circuit or the electrical boxes of the indoor or outdoor unit — refrigerant work is licensed work. The checks on this page stay on the outside: power, filters, remote control and airflow.
  1. Switch the unit off at the breaker or isolator, wait five minutes, then switch it back on and run it again.
  2. Look for water dripping from the indoor unit, and check that the end of the drain hose outside is not blocked, kinked or sitting in water.
  3. If the code returns after these checks, book a Daikin service engineer and tell them the code and the model name from the unit's label.

Clear the code and test

  1. Fix what the checks above found first — a filter cleaned, an obstruction removed, the breaker restored. Clearing the code without fixing the cause only brings it back.
  2. Restore power at the breaker and switch the unit on with the remote.
  3. Run the unit in cooling or heating for ten to fifteen minutes and watch whether the code returns; some codes only appear after the compressor has run for a while.
  4. If the unit runs with no code, the fault is cleared. If the code returns, write down the code and whether the indoor or outdoor unit shows it before calling a technician — it speeds up the diagnosis.

When to call a professional

Most cases are solved by the checks above. Book a technician if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code A3, your model number (on a label on the side of the indoor unit) and the checks you already ran. It shortens the visit.

Parts that may be involved

Drain pumpFloat switchDrain hose

Parts are model-specific. Find your model number first — usually on a label on the side of the indoor unit — and match the part to that number before ordering.

Questions people ask about A3

What does A3 mean on a Daikin air conditioner?

A3 means: Drain water level is too high. Condensate water is not draining away, so the float switch has stopped the unit before it overflows. A blocked or badly sloped drain is the most common cause; on units with a built-in pump, the pump or float switch may have failed.

Can I fix Daikin A3 myself?

Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.

How do I clear Daikin A3?

Fix what the checks above found first — a filter cleaned, an obstruction removed, the breaker restored. Clearing the code without fixing the cause only brings it back. Restore power at the breaker and switch the unit on with the remote. Run the unit in cooling or heating for ten to fifteen minutes and watch whether the code returns; some codes only appear after the compressor has run for a while.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Daikin air conditioner codes

See all Daikin air conditioner error codes